Baumer BA OADM20x659x Manual de usuario Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
Manual_OADM20x659_DE_EN.doc
43/48
Baumer
04.12.12 Frauenfeld, Switzerland
Sensor
t1 t2
OADM 20I6591 < 2 ms 1.5 ... 6 ms
OADM 20I6592 < 2.5 ms 1.5 ... 7.5 ms
OADM 20I6593 < 3.5 ms 1.5 ... 10.5 ms
t1 is the max. time after a high signal on the synch. input of S1 until the analog value will be held. This value
will be held as long the signal on the synch. input is high.
The min. time between the high signal of S1 and the low signal of S2 is t1, also. In this case, an optical
influence between the sensors is not possible.
t2 is the time until the analog signal is ready after a low signal on the synch. input of S2. This time depends
on the reflectivity of the object and if the reflectivity changes during the hold time.
Input circuit
27k
10k
sync in
low: 0 .. 2V
high: 12 .. 28V
3V3
Vista de pagina 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48

Comentarios a estos manuales

Sin comentarios