8 Technical data
8 Technical data
8.1 Technical data - electrical ratings
Consumption w/o load: ≤200 mA
Sensing method: Optical
Interference immunity: EN 61000-6-2:2005
Emitted interference: EN 61000-6-3:2007/A1:2011
HOG 16 + DSL.E
Voltage supply: 9...30 VDC
HOG 16 + DSL.R
Voltage supply: 15...30 VDC
8.2 Technical data - electrical ratings (encoder)
Pulses per revolution: 512...2500 (As precised on order)
Phase shift: 90° ±20°
Duty cycle: 40...60 %
Reference signal: Zero pulse, width 90°
Output frequency: 120 kHz
Output signals: K1, K2, K0 + inverted
Output stage: HTL
TTL/RS422
(As precised on order)
8.3 Technical data - electrical ratings (speed switches)
Interface: RS485
Switching accuracy: ±2 % (Digit)
Switching delay time: 40 ms
HOG 16 + DSL.E
Switching outputs: 2 outputs, speed control
1 control output
Output switching capacity: 5...230 VAC/VDC; 5...250 mA
HOG 16 + DSL.R
Switching outputs: 3 outputs, speed control
Output switching capacity: 12 VDC; ≤40 mA