18
Technical data 9
9 Technical data
9.1 Technical data - electrical ratings
Voltage supply: 9...30 VDC* (HTL-P, TTL)
5 VDC ±5 % (TTL)
Consumptionw/oload: ≤100mA
Pulses per revolution: 300...5000 (As ordered)
Phase shift: 90° ±20°
Scan ratio: 40...60 %
Reference signal: Zero pulse, width 90°
Sensing method: Optical
Outputfrequency: ≤120kHz
300kHzoption
Output signals: K1, K2, K0 + inverted
Output stages:
HTL-P (power linedriver)
TTL/RS422
(As ordered)
Interference immunity: EN 61000-6-2:2005
Emitted interference: EN 61000-6-3:2007/A1:2011
Approvals: CE, UL approval / E256710
9.2 Technical data - mechanical design
Size(ange): ø115mm
Shafttype: ø11mmsolidshaft
Shaftloading: ≤300Naxial;≤450Nradial
Flange: EUROangeB10
Protection DIN EN 60529: IP66
Operatingspeed: ≤12000rpm(mechanical)
Operating torque typ.: 2 Ncm
Rotor moment of inertia: 340 gcm
2
Materials: Housing: stainless steel
Shaft: stainless steel
Operating temperature: -40**…+90 °C, UL up to +80 °C
Restricted in potentially explosive environments, see section 2.
Resistance: IEC 60068-2-6:2007
Vibration 20 g, 10-2000 Hz
IEC 60068-2-27:2008
Shock 200 g, 6 ms
Explosion protection: II 3 G Ex nA IIC T4 Gc (gas)
II 3 D Ex tc IIIC T135°C Dc (dust)
Connection: Connecting cable
Weight approx.: 4.7 kg
* The voltage supply is 9...26 VDC at TTL - version R for versions <95 pulses per revolution
** Up to -25 °C for versions >3072 pulses per revolution