8.4 Technical data - electrical ratings (sinewave)
Voltage supply (Signals): P...D: 4,5...30 VDC (SinCos)
Consumptionw/oload: 300mA
Sinewave cycles per turn: 1...8192 (As ordered)
Phase shift: 90° ±5°
Sensing method: Magnetic
Output signals: A+, A-, B+, B-
Output stage: SinCos 1 Vpp
DifferenceofSinCosamplitude: ≤20mV
Harmonics typ.: -40 dB
DCoffset: ≤20mV
Bandwidth: 400kHz(-3dB)
8.5 Technical data - mechanical design
Sensor head: FPGA signal processing
Size(ange): ø101.3mm
Shafttype: ø16...80mm(throughhollowshaft)
(As ordered)
Axial tolerance: ±1 mm (wheel/head)
Radial tolerance: 0.1...0.5 mm (wheel/head)
Protection DIN EN 60529: IP 67 (head)
IP 68 (wheel)
Operating temperature: -20...+85 °C
Operatingspeed: ≤8000rpm
Resistance: IEC 60068-2-6:2007
Vibration30g,55-2000Hz
IEC 60068-2-27:2008
Shock 300 g, 2 ms
Accuracyofmagneticmeasure: ±400″
Connection: Flange connector M23, 17-pin