20101215_Shortmanual_ScatecDCC_EN.doc 8/10 Baumer Electric AG
15.12.2010 / wej Frauenfeld, Switzerland
2.3 Checking the adjustment
In normal use with magazines in the gripper the functional LED has not to blink.
3 DIP-Switches
Parameter Dip-Switch Position Value Remark to dead time
Inactive 15% if DIP 3 = ON
Double copy counting
Active 7% if DIP 3 = ON
Pulse
Counting signal output
Synchronous
Minimal 1%
Dead time
Maximal Defined by DIP 1
Maximal
Sensitivity
Reduced
Signal from
synchronization sensor
Signal from magazin
Signal from magazin
Signal from magazin
15%
85%
100%
It is ok.
orange LED flashing: Position to fare away
green LED flashing: Position to close