Baumer BA OADM20x24 Manual de usuario Pagina 34

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 39
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 33
BA_OADM20x24.doc
34/39
Baumer
05.12.12 Frauenfeld, Switzerland
5.2 How to reset the factory settings using the teach button
Within 5 minutes after power up, the button may be used to reset the sensor back to the factory settings.
After finishing a teach procedure, the 5 minutes starts again. After the 5 minutes, the sensor does not
respond to the button.
1. Push the button. The red LED will turn on, if the sensor can be taught.
2. Hold down the button further 5 sec. The LED will start to blink. DO NOT RELEASE the button now. Wait
another 10 sec until the LED is ON without blinking. Factory settings have been restored to the sensor.
3. Release the button.
5.3 How to teach a new range using the external teach input
Teaching the sensor via the external teach input is equivalent to the teaching procedure via the button. There
is no 5 min. time limit. The sensor may be taught at any time.
Input circuit:
t1
Red LED
t12
Until button has been
released (t13)
27k
10k
teach-in
low: 0 .. 2V
high: 12 .. 28V
3V3
t
Red LED
t1
t2
t3
t4
0 V
12-28 V
Teach wire
t7 t8
t9
t6
Vista de pagina 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39

Comentarios a estos manuales

Sin comentarios