9. Operating plan
Line Display Short description
01 0 0 0 0 0 0.0 0 Preselection Counter XP
02 1.0 0 Preselection 1
03 1 0.0 0 Preselection 2
04 Not applicable
05 0 0 0 0 0 0.0 0 Totalizer
06 0 Batch counter
07 1 0 Preselection Batch counter
08 0.0 Operating time meter
10 - - - - - - - - Separating line
11 S t A t 0 Status of preselection Counter XP
12 S t A t 0 Status of preselection 1
13 S t A t 0 Status of preselection 2
14 Not applicable
15 S t A t 0 Status of totalizer
16 S t A t 0 Status of batch counter
17 S t A t 0 Status of batch counter preselection
18 S t A t 0 Status of operating time meter
20 - - - - - - - - Separating line
21 2 1 0 Operating mode Main count system
22 Not applicable
23 2 3 0 Scaling factor Batch counter
24 Not applicable
25 Not applicable
26 2 6 0 Frequency Batch counter Counting input
27 Not applicable
28 Not applicable
29 Not applicable
30 3 0 0 Reset Batch counter
31 3 1 0.2 5 Output time P1
32 3 2 0.2 5 Output time P2
33 3 3 0.2 5 Output time P3
34 3 4 0 Take-over of preselections P1, P2, B1
35 3 5 0 Address of function key
36 3 6 0 Function of batch counter
37 3 7 1.0 0 Impulses per unit of tachometer
38 3 8 0 Selection of time base for the tachometer
functions
39 Not applicable
40 4 0 0 Operating time meter input
41 4 1 0 0 0 0 Code setting
42 - - - - - - - - Separating line
43 4 3 0 Baud rate
44 4 4 0 Parity
45 4 5 0 0 Address
46 4 6 0 Stop bit
47 - - - - - - - - Separating line
Vista de pagina 17