19
NE215Programming mode
Line 36
Secondary counter functions XB
0 * External
1
Internal
2
Tachometer
Line 37
Pulses per unit of measurement, as tachometer
1.0 0 * 1, 00
0,01 - 9999.99
Line 38
Input of time measurement in seconds (s)
0 * Time base 1 s
1
Time base 2 s
2
Time base 3 s
3
Time base 6 s
4
Time base 10 s
5
Time base 20 s
6
Time base 30 s
7
Time base 60 s
The time base must be selected in accordance with the pulse
rate.
Examples
Line 40
Function input time meter
0 *
Operating hours with supply
on/off
1 Operating hours on/off
Line 41
Code setting
0 *No code
1 -9999
At the conclusion of these programming lines, a broken line will
appear in the display, signifying the competion of the third
programming segment.
Pulses per rev. Time base in seconde
60 pulses/rev 1 s
< 60 30 pulses/rev 2 s
to to
1 pulses/rev 60 s